Slow osd heartbeats on back longest
Webb8 sep. 2024 · Long heartbeatping times on backinterfaceseen, longest is 1118. 097 msec Long heartbeatping times on front interfaceseen, longest is 22418. Oct 18, 2016 · At the next moment, osd. 2024. Our OSD-hosts have 64 GB of RAM for 32 OSDs, which should be fine withthe default bluestore cache size of 1 GB.
Slow osd heartbeats on back longest
Did you know?
Webb11 nov. 2024 · 4:57 p.m. Hi We’ve recently encountered the following errors: [WRN] OSD_SLOW_PING_TIME_BACK: Slow OSD heartbeats on back (longest 2752.832ms) … WebbCeph is a distributed storage system, so it relies upon networks for OSD peering and replication, recovery from faults, and periodic heartbeats. Networking issues can cause OSD latency and flapping OSDs. See Flapping OSDs for details. Ensure that Ceph processes and Ceph-dependent processes are connected and/or listening.
WebbI just setup a Ceph storage cluster and right off the bat I have 4 of my six nodes with OSDs flapping in each node randomly. Also, the health of the cluster is poor: root@clusterhead-sp01:/home/pcc# ceph health detail HEALTH_WARN 24 slow ops, oldest one blocked for 22525 sec, mon.clusterhead-lf04 has slow ops SLOW_OPS 24 slow ops, oldest one ... WebbOne or more OSDs have exceeded the backfillfull threshold or would exceed it if the currently-mapped backfills were to finish, which will prevent data from rebalancing to this OSD. This alert is an early warning that rebalancing might be unable to complete and that the cluster is approaching full.
WebbHEALTH_WARN Slow OSD heartbeats on back (longest 1118.001 ms) The health detail will add the combination of OSDs are seeing the delays and by how much. There is a limit of … Webb11 juli 2024 · Slow OSD heartbeats on front (longest 22272.255ms) Slow OSD heartbeats on front from osd.8 [] to osd.2 [] 22272.255 msec Slow OSD heartbeats on front from …
Webb10 jan. 2024 · OSD_SLOW_PING_TIME_BACK Long heartbeat ping times on back interface seen health: HEALTH_WARN Long heartbeat ping times on back interface seen, longest …
WebbI suggest you following plan: 1 - check that you created osd correctly and two OSDs didn’t use the same optane partition for blockdb. 2 - delete and recreate OSD.8 1 - check blockdb. See OSDs mount points in df -h. I can’t check real path at this moment. I.e. /opt/ceph/osd.8 ls -al /opt/ceph/osd.*/block.db crystal herb shop near meWebb21 nov. 2024 · Problem was, it was dead slow. server operator() health checks: Last seen:. Ceph MON nodes. Monitoring a cluster typically involves checking OSD status, monitor status, placement group status and metadata server status. . 1a #Checks file exists on. Here are the steps followed (unsuccessful): # 1 destroy the failed osd (s) for i in 38 41 … crystal hermannWebb7 okt. 2024 · Long heartbeat ping times on back interface seen, longest is 1202.120 msec Long heartbeat ping times on front interface seen, longest is 1535.191 msec 35 slow ops, oldest one blocked for 122 sec, daemons [osd.135,osd.14,osd.141,osd.143,osd.149,osd.15,osd.151,osd.153,osd.157,osd.162]... dwh8Webb26 feb. 2024 · If there's a memory leak or some other part of the OSD is using more memory than it should, it will shrink the caches to some base minimum at which point it can't do anything more and the memory usage will exceed the target. It sounds like you might be hitting that case. crystal hermanWebb[root@gibba001 ~]# ceph -s cluster: id: f9d4cf6a-edcf-11ec-a96a-3cecef3d8fb8 health: HEALTH_ERR 1 failed cephadm daemon(s) Slow OSD heartbeats on back (longest 2552.612ms) Slow OSD heartbeats on front (longest 2555.707ms) Upgrade: failed due to an unexpected exception services: mon: 4 daemons, quorum … crystal hermanson helena mtWebb30 jan. 2024 · In the mon log file I can only see messages such as: 2024-01-28 11:14:07.641 7f618e644700 0 log_channel(cluster) log [WRN] : Health check failed: Long heartbeat ping times on back interface seen, longest is 1416.618 msec (OSD_SLOW_PING_TIME_BACK) but the involved OSDs are not reported in this log. dwha arringdonWebb28 sep. 2024 · While it is possible that a busy OSD could delay a ping response, we can assume that if a network switch fails multiple delays will be detected between distinct … dwh69